ComputerWeekly.com.com

RAID 5 recovery: What is the maximum number of physical drives in a RAID 5 configuration?

By David Boyd

What is the maximum number of physical drives in a RAID 5 configuration? For example, will data recovery in case of drive failure(s) be practical if I have seven 146 GB drives?

RAID 5 recovery: A RAID 5 set stripes data and parity information across multiple drives. If a drive fails, data is rebuilt from parity information.

The major benefit of RAID 5 is that it offers resilience to failure with minimum RAID overhead, maximising return on investment.

The minimum number of disks in a RAID 5 set is three (two for data and one for parity). The maximum number of drives in a RAID 5 set is in theory unlimited, although your storage array is likely to have built-in limits. However, RAID 5 only protects against a single drive failure. Two failures within a RAID 5 set will result in data corruption. Increasing the number of drives in your RAID 5 set increases your return on investment but it also increases the likelihood of simultaneous drive failures and lengthens RAID rebuild times. You must consider this trade-off when deciding how many drives to use in a RAID 5 set.

Seven drives in a 6+1 RAID 5 configuration is a standard configuration in many storage environments. Hot spares can be used to mitigate some risk following a drive failure, although the data remains unprotected while rebuilding occurs. If the risk is deemed unacceptable, you should consider RAID 10 or RAID 6 as alternatives, although they will be more expensive to deploy on a "£/usable GB" basis.

More on RAID 5

Using RAID 1 and RAID 5 in a virtual server environment

How to calculate available disk space on a RAID 5 group

23 Aug 2010

All Rights Reserved, Copyright 2000 - 2024, TechTarget | Read our Privacy Statement